Timeless Eleven用戶指南
Previously named Model Eleven
選擇主題
- A. Quick Start
- B. Features
- C. Important Safety Guidelines
- D. Installing and Optimizing Capsules
- E. Pouring Wine
- F. Changing Between Sip & Glass Modes
- G. 取酒器充電
- H. 連接您的 Timeless Eleven至Coravin Moments應用程式
- 清潔取酒器
- J. 清潔取酒針
- K. Traveling with the System
- L. 解決方法
返回頂部
A. Quick Start

How to Pour with Timeless Eleven
返回頂部
B. Features


返回頂部
D. Installing and Optimizing Capsules

充分利用Coravin純淨氬氣囊
On average, each Coravin Pure™ Capsule will enable you to pour about fifteen 5 ounce glasses of wine with Coravin Timeless Systems. To get the most out of each Coravin Pure™ Capsule, we recommend setting your slider to a slower pour speed. If you hear a hissing sound when you stand your bottle up after pouring you are using more Argon gas than is necessary for your pour. Consider decreasing the pour size to ensure better optimization. And, don’t forget, it takes more Argon gas to pour when you get down to the bottom of the bottle, so pull the cork if you know you will be drinking the rest of the bottle that day.
步驟指南
步驟指南

1A. Hold Clamp Release Lever Up. 1B. Slide Clamp all the way up.

2. Unscrew Capsule Cup.

3. Insert round end of Capsule into Capsule Cup.

4. Quickly screw Cup back onto System until there is no gap and Cup is aligned. This ensures a tight seal and no gas loss.

5. Slide Clamp down until it locks into place.

Note: A RED Light Ring indicates Coravin Capsule is empty and needs to be replaced. DO NOT replace Coravin Capsule before Light Ring is RED. It will waste all remaining gas.

Note: Coravin Capsules are made of recyclable materials. EMPTY Capsules can be recycled according to local regulations. DO NOT dispose of unused Capsules.
返回頂部
E. Pouring Wine
NOTE: Use on bottles with natural cork (remove foil to confirm), or on screw cap bottles using Coravin Timeless Screw Caps.
NOTE: Make sure Clamp is in the down position before use.
Step-by-Step Guide
Step-by-Step Guide

1. Pick up System. Light Ring will illuminate BLUE indicating System is ready for use.

2. Place clamp over neck of bottle.

3. Push down with palm of hand on metal surface to insert Needle through cork. Push until Light Ring turns GREEN, indicating System is ready to pour.

4. Hold Spout over glass and tilt bottom of bottle up until wine pours automatically. Light Ring with illuminate GREEN in a cascading motion.

5. Tip bottle upright to stop pouring.

6. Hold bottle with one hand. With other hand, flip up Handle and pull System straight up and off in one swift motion. NOTE: A few drops of residual wine may be seen on top of the cork.

7. Rinse System before storing.

8. Store bottle on its side in temperature controlled area suitable for wine.
返回頂部
F. Changing Between Sip & Glass Modes
Step-by-Step Guide
Step-by-Step Guide

1. Push Button to toggle between “Sip” and “Glass” Modes.

2a. “Sip” pours about 1-2oz (30-60ml) of wine.

2b. “Glass” pours about 5-6oz (150-180ml) of wine.
返回頂部
G. 取酒器充電
Step-by-Step Guide
Step-by-Step Guide

1. Connect the USB cord to any standard USB power adapter, 5V, 2.4A max.

2. Plug USB power adapter into power outlet.

3. Plug smaller end of USB cord into System’s Charger Port. A full charge may take up to two hours. Note: Battery icon will pulse when charging. It will be solid WHITE when fully charged.

4. Disconnect USB cord from System before use.

返回頂部
H. 連接您的 Timeless Eleven至Coravin Moments應用程式
Step-by-Step Guide
Step-by-Step Guide

1. Download and open the Coravin Moments App from the App Store® for iPhones or the Google Play Store for Android.

2. Navigate to “My Coravin Systems” from the main menu.

3. Click “Add a System".

4. Select the “Model Eleven”.

5. Select “Add to My Systems.” The System will automatically pair with the iPhone®. NOTE: You will be asked to create an account during this process.

6. The Bluetooth icon on the Model Eleven and iPhone screen will illuminate when connection is complete.
返回頂部
清潔取酒器

清潔 Coravin Timeless Eleven
分步指南
分步指南

1. 建議先以乾淨暖水持續沖洗出酒口至少5秒。

2. Dry with soft cloth.
返回頂部
J. 清潔取酒針

如何清潔您的Timeless Eleven取酒針
Step-by-Step Guide
Step-by-Step Guide
1. Flip Handle up and twist quarter turn counter-clockwise. Pull up to remove.
2. Run warm, clean water through Spout.
3. Pull Needle by grip, straight up and out of System.

4. Remove Needle following steps 1-3 from previous section: “Thoroughly Cleaning the System”.

5. Insert Needle Clearing Brush into top of Needle and twist to release particles. Remove Brush. Repeat as needed.

6. Submerge open end of Needle Clearing Tool in cup of warm, clean water. Pull plunger to draw water into Tool.

7. Insert Needle into open end of Tool until fully seated.

8. Press plunger quickly to push water through Needle. (Note: Repeat until Needle is clear.)

9. Reassemble System following steps 6-9 from previous section: “Thoroughly Cleaning the System”.
返回頂部
K. Traveling with the System
Step-by-Step Guide
Step-by-Step Guide
System uses a Lithium Ion battery and compressed gas. For air travel, be sure to comply with all airline regulations. Many airlines do not allow travel with compressed gas (Coravin Capsules). To conserve battery while in transit, put System into Travel Mode.

1. Press and hold Button until Sip and Glass Icons blink (about 5 seconds).

2. To disable Travel Mode, push Button once. Note: System will not operate in Travel Mode. Disable by pressing Button once when ready to pour wine.
返回頂部
L. 解決方法
無法取酒。
Probable Cause: System is not completely seated onto wine bottle (Light Ring is still BLUE).
Solution: Push System completely down further onto bottle. Light Ring will turn GREEN.
Probable Cause: Bottle is not tilted enough.
Solution: Raise bottom of bottle higher. System will pour automatically when bottle is tilted enough.
Probable Cause: Battery is empty.
Solution: Charge System.
Probable Cause: Coravin Capsule is empty or missing. Light Ring is RED.
Solution: Install new Coravin Capsule only when Light Ring is RED.
Probable Cause: Needle is clogged or damaged.
Solution: Replace if damaged. If clogged, refer to “Clearing the Needle”.
Probable Cause: Filter in Needle is clogged.
Solution: Refer to “Cleaning the System”
.
取酒速度緩慢。
可能原因: 在結束取酒前,取酒器的速度會減慢。
解決方法: 此乃正常情況。臨近尾聲之際,取酒速度會減慢。
可能原因: 進入淺嚐模式。淺嚐標誌亮起。
解決方法: 按下按鈕,即可關閉淺嚐模式,加快取酒速度。
可能原因: 取酒針阻塞或受損。
解決方法: 如有損壞,請即更換。如有阻塞,請參閱「清潔取酒針」。
可能原因: 取酒針的過濾器受阻。
解決方法: 請參閱「清潔取酒器」。
難以從酒瓶插入或移除取酒器。
可能原因: 取酒針塗層磨損。
解決方法: 如果取酒針頭磨損或損壞,請即更換。
可能原因: 部分軟木塞阻力較大。
解決方法: 此乃正常情況。透過手柄增強槓桿作用,從酒瓶移除取酒器。
可能原因: 密封夾積聚葡萄酒。
解決方法: 以乾淨暖水徹底沖洗密封夾。請參閱「清潔取酒器」。
The cork is leaking/dripping.
Probable Cause: Bottle has a plastic cork which does not reseal.
Solution: Only access wines with natural corks.
Probable Cause: System was left in the cork for too long.
Solution: Remove Coravin System immediately after pouring.
Probable Cause: Wine left in Needle sometimes drips onto the top of cork.
Solution: This is normal even if cork has resealed. Wipe top of the cork with paper towel or cloth.
Probable Cause: Cork might be cold, old, or dry and has difficulty resealing.
Solution: Give the cork additional time to reseal.
There are particles in the wine.
Probable Cause: Cork particles or sediment in the wine have passed through Needle.
Solution: This is normal for some wines.
Coravin Moments App for iPhone does not find System via Bluetooth®.
Probable Cause: Bluetooth is not enabled on the iPhone.
Solution: Enable Bluetooth on iPhone.
Probable Cause: Coravin Moments App is not downloaded on iPhone.
Solution: Download Coravin Moments App to iPhone from App Store.
Probable Cause: System is too far from iPhone.
Solution: Move System closer to iPhone.
Probable Cause: System battery is empty.
Solution: Charge System.
Probable Cause: System is connected to different iPhone.
Solution: Disconnect System from other iPhone. System can only be connected to one device at a time.
System is unresponsive.
Probable Cause: System is in Travel Mode.
Solution: Push Button once to exit Travel Mode.
Probable Cause: Battery is empty.
Solution: Charge System.